ifmSV7614

Flow sensor ifm model SV7614

Flow sensor ifm model SV7614,  Part number SV7614

Verify the part number and specifications; the image alone does not establish suitability.

ARAN VISION reference
AV-FEED-13SEAAP
Manufacturer sourcing lead time
Manufacturer confirmation required

Delivery to your location is confirmed separately.

Documents / datasheets
ARAN VISION specification sheet

Technical specifications

Number of inputs and outputs
Number of analogue outputs: 2
Measuring range
80...1585 gph: 1.3...26.4 gpm
Process connection
threaded connection 3/4" NPT internal thread DN20
Special feature
Gold-plated contacts
Application
for industrial applications
Media
water; glycol solutions; coolants
Medium temperature [°F]
14...194
Pressure rating
12 bar: 174 psi: 1.2 MPa
Note on pressure rating
up to 40 °C
MAWP for applications according to CRN [bar]
4.3
Operating voltage [V]
18...30 DC
Current consumption [mA]
< 30
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
< 3
Measuring principle
Vortex
Total number of outputs
2
Output signal
analogue signal
Number of analogue outputs
2
Analogue current output [mA]
4...20
Max. load [Ω]
500
Short-circuit protection
Yes
Overload protection
Yes
Display range
0...1900 gph: 0...31.7 gpm
Resolution
5 gph: 0.1 gpm
Analogue start point ASP
0...1270 gph: 0...21.1 gpm
Analogue end point AEP
315...1585 gph: 5.3...26.4 gpm
In steps of
5 gph: 0.1 gpm
Measuring dynamics
1:20
Measuring range [°F]
14...194
Display range [°F]
-22...230
Resolution [°F]
1
Analogue start point [°F]
14...158
Analogue end point [°F]
50...194
In steps of [°F]
1
Accuracy (in the measuring range)
± 2 % MEW; (water)
Repeatability
± 0,5 % MEW
Accuracy [K]
± 1
Response time [s]
1; (dAP = 0)
Damping process value dAP [s]
0...5
Dynamic response T05 / T09 [s]
T09 = 6
Parameter setting options
Damping for the analogue output dAA; Display unit
Ambient temperature [°F]
32...140
Note on ambient temperature
medium temperature < 176 °F; medium temperature < 194 °F: 32...122 °F
Storage temperature [°F]
-4...176
Protection rating
IP 65; IP 67
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27: 5 g (11 ms)
Vibration resistance
DIN EN 60068-2-6: with water / 10...50 Hz 1 mm; with water / 50...2000 Hz 2 g
MTTF [years]
342
UL approval
UL approval no.: I002
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
514.5
Housing
rectangular
Dimensions [mm]
139 x 45 x 72
Materials
stainless steel (316L/1.4404); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts)
stainless steel (316L/1.4404); ETFE; PA 6T; PPS; FKM
Tightening torque [Nm]
30
Display
colour display 1,44", 128 x 128 pixels; 2 x LED, yellow
Remarks
MW = measured value; MEW = Final value of the measuring range
Pack quantity
1 pcs.
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Report a product-data issue

Documents / datasheets

Source reviewed: 2026-10-24

Description

Flow sensor ifm part number SV7614; Number of inputs and outputs: Number of analogue outputs: 2; Operating voltage [V]: 18...30 DC; Current consumption [mA]: < 30. Technical specifications, condition and supply feasibility are checked before ordering.

Ask about this product

Send the part number and your question for technical or sourcing review.

Condition and order verification

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version