Specialist electrical and industrial automation store
فارسی

Flow sensor ifm model SBN234

Flow sensor ifm model SBN234,  Part number SBN234

Check the part number and technical specifications before selection; an image alone is not sufficient for matching.

Manufacturer part number
SBN234
Manufacturer
ifm
ARAN VISION part number
AV-FEED-1QJNZRY
Product description
Flow sensor ifm part number SBN234; Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1; Measuring range: 10...600 gph: 0.2...10 gpm; Process connection: threaded connection 3/4" NPT internal thread. Technical specifications, condition and supply feasibility are checked before ordering.
Manufacturer standard lead time
Manufacturer confirmation required

Manufacturer replenishment time; delivery to you is confirmed separately.

Product attributes

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
10...600 gph: 0.2...10 gpm
Process connection
threaded connection 3/4" NPT internal thread
Special feature
Gold-plated contacts
Application
for industrial applications
Media
Liquids; water; glycol solutions; coolants; oil (viscosity 10 mm²/s at 104 °F); oil (viscosity 46 mm²/s at 104 °F)
Note on media
oil 1 with viscosity: 10 mm²/s (104 °F); oil 2 with viscosity: 46 mm²/s (104 °F)
Medium temperature [°F]
14...212
Pressure rating
40 bar: 4 MPa
MAWP for applications according to CRN [bar]
40
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
< 50
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
< 3
Total number of outputs
2
Output signal
switching signal; analogue signal; frequency signal; IO-Link; (configurable)
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Switching cycles (mechanical)
10 million
Number of analogue outputs
1
Analogue current output [mA]
4...20
Max. load [Ω]
500
Short-circuit protection
Yes
Overload protection
Yes
Frequency of the output [Hz]
0...10000
Display range
0...720 gph: 0...12 gpm
Resolution
5 gph: 0.1 gpm
Set point SP
5...600 gph: 0.1...10 gpm
Reset point rP
0...595 gph: 0...9.9 gpm
Frequency end point, FEP
40...600 gph: 0.67...10 gpm
In steps of
5 gph: 0.1 gpm
Frequency at the end point FRP [Hz]
10...10000
Measuring dynamics
1:50
Measuring range [°F]
14...212
Display range [°F]
-26...252
Resolution [°F]
2
Set point SP [°F]
16...212
In steps of [°F]
2
Frequency start point, FSP [°F]
14...172
Frequency end point, FEP [°F]
54...212
Accuracy (in the measuring range)
± (4 % MW + 1 % MEW); (Q > 1 l/min; medium and operating temperature: +71,6 °F ± 4K)
Repeatability
± 1 % MEW
Temperature drift
0,9802 °F / K
Accuracy [K]
3 K (77 °F; Q > 1 l/min)
Response time [s]
0.01
Damping process value dAP [s]
0...5
Damping for the analogue output dAA [s]
0...5
Dynamic response T05 / T09 [s]
T09 = 120 (Q > 1 l/min)
Parameter setting options
hysteresis / window; normally open / normally closed; switching logic; current output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO mode
Yes
Required master port type
A
Process data analogue
2
Process data binary
2
Min. process cycle time [ms]
3.2
Supported DeviceIDs
Type of operation: DeviceID; default: 567
Ambient temperature [°F]
32...140
Note on ambient temperature
medium temperature < 176 °F; medium temperature < 212 °F: 32...104 °F
Storage temperature [°F]
5...176
Protection
IP 65; IP 67
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27: 20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]
145
UL approval
UL approval no.: I005; File number UL: E174189
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
752.9
Materials
stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts)
stainless steel (316 / 1.4401); stainless steel (316L/1.4404); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Display
Display unit: 3 x LED, green; switching status: 2 x LED, yellow; measured values: alphanumeric display, red/green 4-digit; programming: alphanumeric display, 4-digit
Remarks
Recommendation: use a 200-micron filter.; All data refer to water (68 °F).; MW = measured value; MEW = Final value of the measuring range
Notes
Please note the changed housing design!
Pack quantity
1 pcs.
Report a product information error
Documents and technical resources
ARAN VISION product sheetView and print specifications
Manufacturer datasheetOpen manufacturer datasheet
Official product pageifm

Source checked: 2026-09-10

Product questions

Send the part number and your question to support to check compatibility, lead time or specifications.

Additional information and order matching

The revision, condition, delivery time and required documentation must be confirmed before the order is finalised. Export classifications and approvals are provided only where valid evidence is available.

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version

The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.

Delivery estimate before ordering

Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.

Technical code verification

Model, revision and equipment compatibility are checked before final confirmation.

Clear product condition

New, surplus or refurbished condition and warranty terms are stated in the quotation.

Products outside the catalog

If this model is unavailable, send the part number or nameplate photo for custom sourcing.

Related products