ifm SV7610

- Manufacturer
- ifm
- Manufacturer part number
SV7610- Description
- Vortex flow meter with display, SVN34XXXIRKG/US-100
- Manufacturer standard lead time
- Manufacturer confirmation required; not a guaranteed delivery date.
Product specifications
- Number of inputs and outputs
- Number of digital outputs: 2
- Measuring range
- 80...1585 gph: 1.3...26.4 gpm
- Process connection
- threaded connection 3/4" NPT internal thread DN20
- Special feature
- Gold-plated contacts
- Application
- for industrial applications
- Media
- water; glycol solutions; coolants
- Medium temperature [°F]
- 14...194
- Pressure rating
- 12 bar: 174 psi: 1.2 MPa
- Note on pressure rating
- up to 40 °C
- MAWP for applications according to CRN [bar]
- 4.3
- Operating voltage [V]
- 18...30 DC
- Current consumption [mA]
- < 30
- Min. insulation resistance [MΩ]
- 100; (500 V DC)
- Protection class
- III
- Reverse polarity protection
- yes
- Power-on delay time [s]
- < 3
- Measuring principle
- Vortex
- Total number of outputs
- 2
- Output signal
- switching signal; frequency signal; IO-Link; (configurable)
- Electrical design
- PNP/NPN
- Number of digital outputs
- 2
- Output function
- normally open / normally closed; (parameterisable)
- Max. voltage drop switching output DC [V]
- 2.5
- Permanent current rating of switching output DC [mA]
- 100
- Short-circuit protection
- yes
- Overload protection
- yes
- Display range
- 0...1900 gph: 0...31.7 gpm
- Resolution
- 5 gph: 0.1 gpm
- Set point SP
- 95...1585 gph: 1.6...26.4 gpm
- Reset point rP
- 80...1570 gph: 1.3...26.2 gpm
- Frequency end point, FEP
- 315...1585 gph: 5.3...26.4 gpm
- In steps of
- 5 gph: 0.1 gpm
- Frequency at the end point FRP [Hz]
- 100...1000
- Measuring dynamics
- 1:20
- Measuring range [°F]
- 14...194
- Display range [°F]
- -22...230
- Resolution [°F]
- 1
- Set point SP [°F]
- 16...194
- Reset point rP [°F]
- 14...192
- In steps of [°F]
- 1
- Frequency start point, FSP [°F]
- 14...158
- Frequency end point, FEP [°F]
- 50...194
- Accuracy (in the measuring range)
- ± 2 % MEW; (water)
- Repeatability
- ± 0,5 % MEW
- Accuracy [K]
- ± 1
- Response time [s]
- 1; (dAP = 0)
- Damping process value dAP [s]
- 0...5
- Dynamic response T05 / T09 [s]
- T09 = 6
- Parameter setting options
- hysteresis / window; normally open / normally closed; switching logic; frequency output; switch-on/switch-off delay; Damping; Display unit
- Communication interface
- IO-Link
- Transmission type
- COM2 (38,4 kBaud)
- IO-Link revision
- 1.1
- SDCI standard
- IEC 61131-9
- Profiles
- Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
- SIO mode
- yes
- Required master port type
- A
- Process data analogue
- 2
- Process data binary
- 2
- Min. process cycle time [ms]
- 3
- Supported DeviceIDs
- Type of operation: DeviceID; default: 494
- Ambient temperature [°F]
- 32...140
- Note on ambient temperature
- medium temperature < 176 °F; medium temperature < 194 °F: 32...122 °F
- Storage temperature [°F]
- -4...176
- Protection
- IP 65; IP 67
- EMC
- DIN EN 61000-6-2; DIN EN 61000-6-3
- Shock resistance
- DIN EN 60068-2-27: 5 g (11 ms)
- Vibration resistance
- DIN EN 60068-2-6: with water / 10...50 Hz 1 mm; with water / 50...2000 Hz 2 g
- MTTF [years]
- 342
- UL approval
- UL approval no.: I001
- Pressure Equipment Directive
- Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
- Weight [g]
- 505.5
- Housing
- rectangular
- Dimensions [mm]
- 139 x 45 x 72
- Materials
- stainless steel (316L/1.4404); PC; PBT+PC-GF30; PPS; TPE-U
- Materials (wetted parts)
- stainless steel (316L/1.4404); ETFE; PA 6T; PPS; FKM
- Tightening torque [Nm]
- 30
- Display
- colour display 1,44", 128 x 128 pixels; 2 x LED, yellow
- Remarks
- MW = measured value; MEW = Final value of the measuring range
- Pack quantity
- 1 pcs.
- Connector
- 1 x M12; coding: A; Contacts: 4, gold-plated
Documents and media
Price and availability
Checking member pricing…
Supply, condition, exact revision and delivery are confirmed before accepting the order. Catalog presence does not mean local stock.