ifm SM6000

ifm SM6000
Manufacturer
ifm
Manufacturer part number
SM6000
Description
Magnetic-inductive flow meter, SMR12GGXFRKG/US-100
Manufacturer standard lead time
Manufacturer confirmation required; not a guaranteed delivery date.

Product specifications

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.1...25 l/min: 0.005...1.5 m³/h
Process connection
threaded connection G 1/2 external thread DN15 flat seal
Special feature
Gold-plated contacts
Application
totaliser function; for industrial applications
Installation
connection to pipe by means of an adapter
Media
conductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]
-10...70
Pressure rating
16 bar: 1.6 MPa
MAWP for applications according to CRN
15.3 bar: 1.53 MPa
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
95; (24 V)
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
5
Measuring principle
magnetic-inductive
Inputs
counter reset
Total number of outputs
2
Output signal
switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
200
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable)
Min. load resistance [Ω]
2000
Pulse output
flow rate meter
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Display range
-30...30 l/min: -1.8...1.8 m³/h
Resolution
0.02 l/min: 0.002 m³/h
Set point SP
0.25...25 l/min: 0.015...1.5 m³/h
Reset point rP
0.1...24.9 l/min: 0.005...1.495 m³/h
Analogue start point ASP
0...20 l/min: 0...1.2 m³/h
Analogue end point AEP
5...25 l/min: 0.3...1.5 m³/h
In steps of
0.02 l/min: 0.002 m³/h
Pulse value
0.00001...30 000 m³
Pulse length [s]
0,01...2
Measuring range [°C]
-20...80
Resolution [°C]
0.2
Set point SP [°C]
-19.2...80
Reset point rP [°C]
-19.6...79.6
Analogue start point [°C]
-20...60
Analogue end point [°C]
0...80
In steps of [°C]
0.2
Accuracy (in the measuring range)
± (0,8 % MW + 0,5 % MEW)
Repeatability
± 0,2% MEW
Accuracy [K]
± 2,5 (Q > 1 l/min)
Response time [s]
0.15; (dAP = 0, T19)
Delay time programmable dS, dr [s]
0...50
Damping process value dAP [s]
0...5
Dynamic response T05 / T09 [s]
T09 = 20 (Q > 1 l/min)
Parameter setting options
Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO mode
yes
Required master port type
A
Process data analogue
3
Process data binary
2
Min. process cycle time [ms]
5
Supported DeviceIDs
Type of operation: DeviceID; default: 569
Ambient temperature [°C]
-10...60
Storage temperature [°C]
-25...80
Protection
IP 67
EMC
DIN EN 60947-5-9
CPA approval
model number: 001MI; accuracy class: -; maximum allowable error: ± 1,5 % FS; Q (min): 0,005 m³/h; Q (t): -; Q (max): 1,5 m³/h
Shock resistance
DIN IEC 68-2-27: 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6: 5 g (10...2000 Hz)
MTTF [years]
162
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
544