Technical specifications

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.1...25 l/min: 0.005...1.5 m³/h
Process connection
threaded connection G 1/2 external thread DN15 flat seal
Special feature
Gold-plated contacts
Application
totaliser function; for industrial applications
Installation
connection to pipe by means of an adapter
Media
conductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]
-10...70
Pressure rating
16 bar: 1.6 MPa
MAWP for applications according to CRN
15.3 bar: 1.53 MPa
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
95; (24 V)
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
5
Measuring principle
magnetic-inductive
Number of Inputs and Type
counter reset
Total number of outputs
2
Output signal
switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
200
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable)
Min. load resistance [Ω]
2000
Pulse output
flow rate meter
Short-circuit protection
Yes
Type of short-circuit protection
pulsed
Overload protection
Yes
Display range
-30...30 l/min: -1.8...1.8 m³/h
Resolution
0.02 l/min: 0.002 m³/h
Set point SP
0.25...25 l/min: 0.015...1.5 m³/h
Reset point rP
0.1...24.9 l/min: 0.005...1.495 m³/h
Analogue start point ASP
0...20 l/min: 0...1.2 m³/h
Analogue end point AEP
5...25 l/min: 0.3...1.5 m³/h
In steps of
0.02 l/min: 0.002 m³/h
Pulse value
0.00001...30 000 m³
Pulse length [s]
0,01...2
Measuring range [°C]
-20...80
Resolution [°C]
0.2
Set point SP [°C]
-19.2...80
Reset point rP [°C]
-19.6...79.6
Analogue start point [°C]
-20...60
Analogue end point [°C]
0...80
In steps of [°C]
0.2
Accuracy (in the measuring range)
± (0,8 % MW + 0,5 % MEW)
Repeatability
± 0,2% MEW
Accuracy [K]
± 2,5 (Q > 1 l/min)
Response time [s]
0.15; (dAP = 0, T19)
Delay time programmable dS, dr [s]
0...50
Damping process value dAP [s]
0...5
Dynamic response T05 / T09 [s]
T09 = 20 (Q > 1 l/min)
Parameter setting options
Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO mode
Yes
Required master port type
A
Process data analogue
3
Process data binary
2
Min. process cycle time [ms]
5
Supported DeviceIDs
Type of operation: DeviceID; default: 569
Ambient temperature [°C]
-10...60
Storage temperature [°C]
-25...80
Protection rating
IP 67
EMC
DIN EN 60947-5-9
CPA approval
model number: 001MI; accuracy class: -; maximum allowable error: ± 1,5 % FS; Q (min): 0,005 m³/h; Q (t): -; Q (max): 1,5 m³/h
Shock resistance
DIN IEC 68-2-27: 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6: 5 g (10...2000 Hz)
MTTF [years]
162
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
544
Report a product-data issue

Documents / datasheets

Source reviewed: 2026-10-24

Description

Flow sensor ifm part number SM6000; Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1; Operating voltage [V]: 18...30 DC; (to SELV/PELV); Current consumption [mA]: 95; (24 V). Technical specifications, condition and supply feasibility are checked before ordering.

Ask about this product

Send the part number and your question for technical or sourcing review.

Condition and order verification

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version

The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.

Delivery estimate before ordering

Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.

Products in the same technical family

Category similarity does not establish compatibility or replacement suitability.