Search by part number, manufacturer or technical specification, then narrow the results with filters.
Authenticity, technical version and delivery information
Authenticity and condition
Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.
Matching technical version
The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.
Delivery estimate before ordering
Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.
Control interface: RS-485 / Modbus RTU; other industrial networks require a separate Oriental Motor network converter; not a direct EtherCAT driverInput current: Main: 0.4–3.7 A depending on motor. Control: 0.15 A standard, 0.4 A brake motor, 0.23 A for AZM46
Protocol roles: BACnet/IP server to Siemens S7 client; not BACnet MS/TP.PLC support: S7-300/400/1200/1500; up to five PLC connections; confirm firmware and PLC access configuration.
PLC controller Siemens part number 6ES72151BG400XB0; Current consumption (rated value): 100 mA at 120 V AC; 50 mA at 240 V AC; number of communications modules (CM): 3; Number of digital inputs: 14; Integrated. Technical specifications, condition and supply feasibility are checked before ordering.
Current consumption (rated value): 100 mA at 120 V AC; 50 mA at 240 V ACnumber of communications modules (CM): 3Number of digital inputs: 14; Integrated
Industrial gateway and protocol converter HMS Networks part number ABC4021-A; Modulation or Protocol: EtherCAT, EtherNet/IP, Modbus TCP, PROFINET; Interface: Ethernet, DB-9, RJ-45; Role: Gateway. Technical specifications, condition and supply feasibility are checked before ordering.
Closed-loop motion driver for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Control interface: RS-485 / Modbus RTU; other industrial networks require a separate Oriental Motor network converter; not a direct EtherCAT driverInput current: Main: 0.4–3.7 A depending on motor. Control: 0.15 A standard, 0.4 A brake motor, 0.23 A for AZM46Positioning data: 256 positioning data sets per exact product page; not physical I/O channels
Machine-vision controller Omron part number FZ5-L350-10; Number of Channels: 4; Voltage - Supply: 20.4 ~ 26.4VDC; Controller Type: Camera. Technical specifications, condition and supply feasibility are checked before ordering.
Number of channels: 4Voltage - Supply: 20.4 ~ 26.4VDCController Type: Camera
Temperature transmitter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Measuring channels: 1Voltage - Supply: 8.5…36 V DC (C530; Ex variant differs)Input: RTD, thermocouple, mV, ohm
Temperature and thermocouple module Allen-Bradley part number 1769-IR6; Input Signal: 0…150 Ω, 0…500 Ω, 0…1000,Ω, 0…3000 Ω; Number Of Channels: 6; Power Supply: 100mA @ 5V DC, 45mA @ 24V DC. Technical specifications, condition and supply feasibility are checked before ordering.
Distance and laser sensor ifm part number OID250; Operating voltage [V]: 10...30 DC; ("supply class 2" to cULus); Current consumption [mA]: 75; (24 V); Number of inputs and outputs: Number of digital outputs: 2. Technical specifications, condition and supply feasibility are checked before ordering.
Operating voltage [V]: 10...30 DC; ("supply class 2" to cULus)Current consumption [mA]: 75; (24 V)Number of inputs and outputs: Number of digital outputs: 2
Industrial protocol gateway for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Protocol roles: BACnet/IP server to Siemens S7 client; not BACnet MS/TP.PLC support: S7-300/400/1200/1500; up to five PLC connections; confirm firmware and PLC access configuration.Read and write capacity: Up to 150 read and 150 write requests per PLC connection; not physical I/O channels. Maximum 400 bytes per scan line.