RTA460BSSC-N2E

Industrial protocol gateway RTA 460BSSC-N2E

RTA460BSSC-N2EProduct image is not available.

Verify the part number and specifications; the image alone does not establish suitability.

ARAN VISION reference
AV-REF-RTA-460BSSC-N2E
Manufacturer sourcing lead time
Manufacturer confirmation required

Delivery to your location is confirmed separately.

Documents / datasheets
ARAN VISION specification sheet

Technical specifications

Protocol roles
BACnet/IP server to Siemens S7 client; not BACnet MS/TP.
PLC support
S7-300/400/1200/1500; up to five PLC connections; confirm firmware and PLC access configuration.
Read and write capacity
Up to 150 read and 150 write requests per PLC connection; not physical I/O channels. Maximum 400 bytes per scan line.
BACnet objects
1200 analog input and 1200 analog output objects; 1600 binary input and 1600 binary output objects; maximum 2800 COV subscriptions.
Supply
12–24 V DC.
Operating temperature
−40 to +85 °C per platform datasheet; application/installation conditions require verification.
Hardware enclosure
5.40 × 3.83 × 1.19 in; 7.6 oz; anodized aluminium; DIN rail or panel mount.
Configuration
Browser-based configuration and data mapping. Exact platform suffix and mounting option must be selected for quotation.
Report a product-data issue

Documents / datasheets

Manufacturer datasheet · 460BSSC-N2E / exact two-page platform datasheet · en · PDFManufacturer source: Real Time Automation · Document author: Real Time Automation, Inc. · Exact model verified · Covered models: 460BSSC-N2E · Checked: 2026-10-14View / print the ARAN VISION specification sheetOfficial manufacturer source · RTA

Source reviewed: 2026-10-14

Description

Industrial protocol gateway for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.

Ask about this product

Send the part number and your question for technical or sourcing review.

Condition and order verification

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version

The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.

Delivery estimate before ordering

Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.

Products in the same technical family

Category similarity does not establish compatibility or replacement suitability.

RTA
460BSSC-NNA1

Industrial protocol gateway RTA 460BSSC-NNA1

Protocol roles: BACnet/IP server to Siemens S7 client; not BACnet MS/TP.PLC support: S7-300/400/1200/1500; up to five PLC connections; confirm firmware and PLC access configuration.

Technical specificationsManufacturer datasheet · 460BSSC-NNA1 / exact two-page platform datasheet · en · PDFManufacturer source: Real Time Automation · Document author: Real Time Automation, Inc. · Exact model verified · Covered models: 460BSSC-NNA1 · Checked: 2026-10-14