Search by part number, manufacturer or technical specification, then narrow the results with filters.
Authenticity, technical version and delivery information
Authenticity and condition
Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.
Matching technical version
The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.
Delivery estimate before ordering
Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.
Power input: 100–240 V AC; frequency and full-load input current unspecifiedPower output: Up to 350 W; 55 V DC, 6.3 A printed (346.5 W arithmetic); not guaranteed downstream PoE budget; thermal derating unknown
Power supply: 100–240 V AC, 50/60 Hz, 1.8 A; 120–370 V DC input also stated; DC current unspecifiedPower output: 24 V DC, 2.5 A, 60 W nominal; not 48 V; no guaranteed 60 W downstream PoE budget; output adjustment and thermal derating curve not supplied
Power supply: Input 100–240 V AC, 50/60 Hz, 1.8 A; 125–370 V DC input also stated; DC input current not specifiedPower output: 48 V DC, 2.5 A, 120 W nominal; temperature derating curve and output adjustment range not supplied; not a guaranteed 120 W downstream PoE budget
Power supply: PoE input 15.4/30/60/95 W in power bullet, but 90 W on cover and output table; confirm input rating; no external DC adapter requiredPower consumption: 7 W maximum for splitter only; connected device consumption excluded
Power supply: PoE input 15.4/30/60/90 W; IEEE 802.3af/802.3at/802.3bt; no external DC adapter requiredPower consumption: 1.13 W maximum for splitter only; connected device consumption excluded
Industrial temperature monitoring controller for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.Communication: RS-485 Modbus RTU/ASCII, daisy chain; Bluetooth configuration via compatible tools.
Industrial temperature monitoring controller for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.Communication: RS-485 Modbus RTU/ASCII, daisy chain; Bluetooth configuration via compatible tools.
Industrial software platform for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Official software identifier: Ignition Edge IIoTVersion scope: 8.3 release/documentation branch; exact installed patch must be confirmed.Application: Industrial edge data acquisition and MQTT publishing; compatible modules and license required.
Industrial software platform for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Official software identifier: Ignition Edge PanelVersion scope: 8.3 release/documentation branch; exact installed patch must be confirmed.Application: Local HMI and fallback visualization with Edge IIoT capabilities; license required.
Industrial network equipment enclosure for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Hardware version: v1.0RApplication: Passive enclosure for industrial switches, fiber converters and PoE injectors; active equipment excludedProtection rating: IP66 enclosure; installed cable entries and modifications require sealing verification
Industrial network equipment enclosure for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Power input: 100–240 V AC; frequency and full-load input current unspecifiedPower output: Up to 350 W; 55 V DC, 6.3 A printed (346.5 W arithmetic); not guaranteed downstream PoE budget; thermal derating unknownHardware version: v1.xR
Industrial DIN-rail power supply for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Power supply: 100–240 V AC, 50/60 Hz, 1.8 A; 120–370 V DC input also stated; DC current unspecifiedPower output: 24 V DC, 2.5 A, 60 W nominal; not 48 V; no guaranteed 60 W downstream PoE budget; output adjustment and thermal derating curve not suppliedHardware version: v1.0R; TRENDnet package identifies Mean Well MDR-60-24
Industrial Ethernet surge protector for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Power supply: Nominal PoE voltage <60 V; inline pass-through, no generated power supply statedHardware version: V1 on document cover; filename v1.xRPorts: 1 × 2.5 Gbps RJ45 Line In; 1 × 2.5 Gbps RJ45 Device Out; ground terminal; inline surge protector, not a switch or injector
Industrial DIN-rail power supply for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Power supply: Input 100–240 V AC, 50/60 Hz, 1.8 A; 125–370 V DC input also stated; DC input current not specifiedPower output: 48 V DC, 2.5 A, 120 W nominal; temperature derating curve and output adjustment range not supplied; not a guaranteed 120 W downstream PoE budgetHardware version: v1.0R; TRENDnet identifies packaged supply as Mean Well SDR-120-48
Industrial 10G PoE++ splitter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Power supply: PoE input 15.4/30/60/95 W in power bullet, but 90 W on cover and output table; confirm input rating; no external DC adapter requiredPower consumption: 7 W maximum for splitter only; connected device consumption excludedHardware version: v2.xR on document cover
Industrial 10G PoE++ splitter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Power supply: PoE input 15.4/30/60/90 W; IEEE 802.3af/802.3at/802.3bt; no external DC adapter requiredPower consumption: 1.13 W maximum for splitter only; connected device consumption excludedHardware version: V1 on document cover