Number of inputs and outputs
Number of digital outputs: 2
Measuring range
-1...10 bar: -14.5...145 psi: -0.1...1 MPa
Process connection
threaded connection G 1/4 internal thread
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
liquids and gases
Medium temperature [°C]
-25...80
Min. burst pressure
150 bar: 2175 psi: 15 MPa
Pressure rating
75 bar: 1087 psi: 7.5 MPa
Vacuum resistance
-1000 mbar: -0.1 MPa
Type of pressure
relative pressure; vacuum
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
< 35
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
< 0.3
Integrated watchdog
Yes
Total number of outputs
2
Output signal
switching signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2.5
Permanent current rating of switching output DC [mA]
150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC [Hz]
< 170
Short-circuit protection
Yes
Type of short-circuit protection
pulsed
Overload protection
Yes
Set point SP
-0.9...10 bar: -13.5...145 psi: -0.09...1 MPa
Reset point rP
-0.95...9.95 bar: -14...144.5 psi: -0.095...0.995 MPa
Min. difference between SP and rP
0.05 bar: 1 psi: 0.005 MPa
In steps of
0.05 bar: 0.5 psi: 0.005 MPa
Set point SP
-0.92...10 bar: -13.3...145 psi: -0.092...1 MPa
Reset point rP
-0.97...9.95 bar: -14...144.3 psi: -0.097...0.995 MPa
Min. difference between SP and rP
0.05 bar: 0.8 psi: 0.005 MPa
In steps of
0.01 bar: 0.1 psi: 0.001 MPa
Switch point accuracy [% of the span]
< ± 0,5
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]
< ± 0,25
Long-term stability [% of the span]
< ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]
< ± 0,2; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]
< ± 0,2; (0...80 °C)
Response time [ms]
< 3
Delay time programmable dS, dr [s]
0...50
Parameter setting options
hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
SIO mode
Yes
Required master port type
A; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operation: DeviceID; Factory setting / CMPT = 2: 403; Status_B High Resolution / CMPT = 3: 601
Note
For further information please see the IODD PDF file under "Downloads"
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
Min. process cycle time [ms]
2.3
IO-Link resolution pressure
0.01 bar: 0.001 MPa
IO-Link process data (cyclical)
function: bit length; pressure: 14; binary switching information: 2
IO-Link functions (acyclical)
application specific tag
Profiles
Smart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis
Min. process cycle time [ms]
3
IO-Link resolution pressure
0.005 bar: 0.0005 MPa
IO-Link process data (cyclical)
function: bit length; pressure: 16; device status: 4; binary switching information: 2
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection rating
IP 65; IP 67
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]
260
UL approval
UL approval no.: J001
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
241.7
Housing
cylindrical
Dimensions [mm]
Ø 34 / L = 90.7
Materials
stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)
stainless steel (316L/1.4404); ceramics; FKM
Min. pressure cycles
100 million