ARAN VISION logo

ARAN VISION

Product specification sheet

SV4204Document: AV-FEED-GE14NV
Flow sensor ifm model SV4204,  Part number SV4204

ifm · Sensors and machine vision

Flow sensor ifm model SV4204

Flow sensor ifm part number SV4204; Number of inputs and outputs: Number of analogue outputs: 2; Operating voltage [V]: 18...30 DC; Current consumption [mA]: < 30. Technical specifications, condition and supply feasibility are checked before ordering.

Manufacturer part number
SV4204
Brand
ifm
Category
Sensors and machine vision
Catalog status
Available on request

Technical specifications

Number of inputs and outputs
Number of analogue outputs: 2
Measuring range
1...20 l/min: 0.06...1.2 m³/h
Process connection
threaded connection G 1/2 internal thread DN8
Special feature
Gold-plated contacts
Application
for industrial applications
Media
water; glycol solutions; coolants
Medium temperature [°C]
-10...90
Pressure rating
12 bar: 1.2 MPa
Note on pressure rating
up to 40 °C
MAWP for applications according to CRN [bar]
3.9
Operating voltage [V]
18...30 DC
Current consumption [mA]
< 30
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
< 3
Measuring principle
Vortex
Total number of outputs
2
Output signal
analogue signal
Number of analogue outputs
2
Analogue current output [mA]
4...20
Max. load [Ω]
500
Short-circuit protection
Yes
Overload protection
Yes
Display range
0...24 l/min: 0...1.44 m³/h
Resolution
0.1 l/min: 0.005 m³/h
Analogue start point ASP
0...16 l/min: 0...0.96 m³/h
Analogue end point AEP
4...20 l/min: 0.24...1.2 m³/h
In steps of
0.1 l/min: 0.005 m³/h
Measuring dynamics
1:20
Measuring range [°C]
-10...90
Display range [°C]
-30...110
Resolution [°C]
0.5
Analogue start point [°C]
-10...70
Analogue end point [°C]
10...90
In steps of [°C]
0.5
Accuracy (in the measuring range)
± 2 % MEW; (water)
Repeatability
± 0,5 % MEW
Accuracy [K]
± 1
Response time [s]
1; (dAP = 0)
Damping process value dAP [s]
0...5
Dynamic response T05 / T09 [s]
T09 = 6
Parameter setting options
Damping for the analogue output dAA; Display unit
Ambient temperature [°C]
0...60
Note on ambient temperature
medium temperature < 80 °C; medium temperature < 90 °C: 0...50 °C
Storage temperature [°C]
-20...80
Protection rating
IP 65; IP 67
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
CPA approval
model number: 001VO; accuracy class: -; maximum allowable error: ± 2 % FS; Q (min): 0,09 m³/h; Q (t): 0,24 m³/h; Q (max): 1,2 m³/h
Shock resistance
DIN EN 60068-2-27: 5 g (11 ms)
Vibration resistance
DIN EN 60068-2-6: with water / 10...50 Hz 1 mm; with water / 50...2000 Hz 2 g
MTTF [years]
342
UL approval
UL approval no.: I002
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
439.5
Housing
rectangular
Dimensions [mm]
110 x 45 x 72
Materials
stainless steel (316L/1.4404); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts)
stainless steel (316L/1.4404); ETFE; PA 6T; PPS; FKM
Tightening torque [Nm]
30
Display
colour display 1,44", 128 x 128 pixels; 2 x LED, yellow
Remarks
MW = measured value; MEW = Final value of the measuring range
Pack quantity
1 pcs.
Connector
1 x M12; coding: A; Contacts: 4, gold-plated

This sheet provides a quick technical summary. For design, installation and final selection, review the latest official manufacturer documentation and verify the complete part number.