نشان ARAN VISION

ARAN VISION

Datasheet فنی محصول

150-C201NBDDocument: AV-FEED-XUMFF3
Industrial controller Allen-Bradley model 150-C201NBD,  Part number 150-C201NBD

Allen-Bradley · PLC and HMI

Industrial controller Allen-Bradley model 150-C201NBD

Industrial controller Allen-Bradley part number 150-C201NBD; Lifecycle Status: Active; Repair Options Available: Yes; Sub Brand: SMC-3. Technical specifications, condition and supply feasibility are checked before ordering.

Manufacturer part number
150-C201NBD
Brand
Allen-Bradley
Category
PLC and HMI
Status فهرست
Available on request

Specifications فنی

Lifecycle Status
Active
Repair Options Available
Yes
Sub Brand
SMC-3
Altitude
2000 m
Break
TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Cable size
0.2...2.5 mm2 (24...14 AWG) for control terminals
Controller type
SMC-3
Conventional thermal current (Ith)
TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Degree of protection (IP)
IP2X
Delta connected motor current
116...348A @ 380/400/415/460V AC, 3-phase
Delta connected motor power, max
75...125Hp @ 230V AC, 60 Hz, 3-phase
Depth
265.3 mm (10.45 in)
Dielectric withstand
2500V AC per IEC for power circuit
DV/DT protection
1000V/µs for power circuit
EMC emission levels
Radiated emission: Class A per IEC
EMC immunity levels
Surge transient: per EN/IEC 60947-4-2 per IEC
Enclosure
Open type
Fan power rating
40 VA
Function
Single direction
Height
560 mm (22.05 in)
High capacity available fault current, max
70kA @ 600V, maximum current 600 A time delay Class J or Class L fuse for inside delta connected motors
Humidity
5...95% noncondensing
Input OFF-state current
<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Input OFF-state voltage (IN1, IN2), max
40V AC @ 17V DC/12V AC for control circuit
Input ON-state current (IN1, IN2)
9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Input ON-state voltage, during start (IN1, IN2)
85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Insulation voltage
Rated 600V AC per UL/CSA/NEMA for power circuit
Integrated motor overload protection
true
Internal bypass
true
Line connected motor current
67...201A @ 380/400/415/460V AC, 3-phase
Line connected motor power, max
95...110 kW @ 380/400/415V AC @ 50Hz, 3-phase
Make
TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Mounting hole size
11.5 mm
Number of contacts
TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
Number of poles
Equipment is designed for 3-phase only for power circuit
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit

این برگه, خلاصه فارسی Specifications محصول for Quick links است. for طراحی, Mounting and انتخاب نهایی, آخرین Official manufacturer documentation and تطابق Complete Part number بررسی شود.