Allen-Bradley150-C201NBD

Industrial controller Allen-Bradley model 150-C201NBD

Industrial controller Allen-Bradley model 150-C201NBD,  Part number 150-C201NBD

Verify the part number and specifications; the image alone does not establish suitability.

ARAN VISION reference
AV-FEED-XUMFF3
Category
PLC and HMI
Manufacturer sourcing lead time
Manufacturer confirmation required

Delivery to your location is confirmed separately.

Documents / datasheets
ARAN VISION specification sheet

Technical specifications

Lifecycle Status
Active
Repair Options Available
Yes
Sub Brand
SMC-3
Altitude
2000 m
Break
TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Cable size
0.2...2.5 mm2 (24...14 AWG) for control terminals
Controller type
SMC-3
Conventional thermal current (Ith)
TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Degree of protection (IP)
IP2X
Delta connected motor current
116...348A @ 380/400/415/460V AC, 3-phase
Delta connected motor power, max
75...125Hp @ 230V AC, 60 Hz, 3-phase
Depth
265.3 mm (10.45 in)
Dielectric withstand
2500V AC per IEC for power circuit
DV/DT protection
1000V/µs for power circuit
EMC emission levels
Radiated emission: Class A per IEC
EMC immunity levels
Surge transient: per EN/IEC 60947-4-2 per IEC
Enclosure
Open type
Fan power rating
40 VA
Role
Single direction
Height
560 mm (22.05 in)
High capacity available fault current, max
70kA @ 600V, maximum current 600 A time delay Class J or Class L fuse for inside delta connected motors
Humidity
5...95% noncondensing
Input OFF-state current
<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Input OFF-state voltage (IN1, IN2), max
40V AC @ 17V DC/12V AC for control circuit
Input ON-state current (IN1, IN2)
9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Input ON-state voltage, during start (IN1, IN2)
85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Insulation voltage
Rated 600V AC per UL/CSA/NEMA for power circuit
Integrated motor overload protection
true
Internal bypass
true
Line connected motor current
67...201A @ 380/400/415/460V AC, 3-phase
Line connected motor power, max
95...110 kW @ 380/400/415V AC @ 50Hz, 3-phase
Make
TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Mounting hole size
11.5 mm
Number of contacts
TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
Number of poles
Equipment is designed for 3-phase only for power circuit
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Report a product-data issue

Documents / datasheets

Source reviewed: 2026-10-24

Description

Industrial controller Allen-Bradley part number 150-C201NBD; Conventional thermal current (Ith): TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts; Delta connected motor current: 116...348A @ 380/400/415/460V AC, 3-phase; Delta connected motor power, max: 75...125Hp @ 230V AC, 60 Hz, 3-phase. Technical specifications, condition and supply feasibility are checked before ordering.

Ask about this product

Send the part number and your question for technical or sourcing review.

Condition and order verification

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version

The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.

Delivery estimate before ordering

Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.

Products in the same technical family