Search by part number, manufacturer or technical specification, then narrow the results with filters.
Authenticity, technical version and delivery information
Authenticity and condition
Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.
Matching technical version
The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.
Delivery estimate before ordering
Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.
Communication: USB, RS-232 or Ethernet via selected module; wireless options depend on reader and base station.Model selection: DM8700 DQ model; corded/wireless configuration and orderable article must be confirmed for quotation.
Main input current: Single-phase 1.6–3.9 A; three-phase 1.0–2.3 A; motor-dependent. Supply current, not motor output rating.Digital interface: 6 control inputs; 6 control outputs; 2 pulse inputs and 2 pulse outputs.
Multiprotocol servo drive; the parameters below follow English datasheet 8143164. Motor selection and network configuration require review of the application documentation.
Nominal operating voltage: 230 V AC; single phase; -20% / +15%Nominal current per phase: 4 A effectivePeak current per phase: 12 A effective; maximum 2 s
Industrial protocol gateway for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Serial interface: RS-232; RS-422; 2-wire RS-485Protocols: Modbus RTU Master / Slave; Modbus ASCII Master / SlavePower supply: 12–56 V DC primary and redundant inputs; TI-M6024 sold separately
Industrial temperature monitoring controller for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.Communication: RS-485 Modbus RTU/ASCII, daisy chain; Bluetooth configuration via compatible tools.
Compact W4 photoelectric sensor with PNP output, red light and background suppression for reliable part detection in production and washdown environments.
Power supply: 10 to 30V DCSensing type: Diffuse With background suppressionMaximum range: 4 to 500 mm
Industrial handheld barcode reader for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Communication: USB, RS-232 or Ethernet via selected module; wireless options depend on reader and base station.Model selection: DM8700 DQ model; corded/wireless configuration and orderable article must be confirmed for quotation.Imager: 1440 × 1080 pixels; 1/3-inch CMOS; 3.45 μm pixels.
Closed-loop motion driver for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Main input current: Single-phase 1.6–3.9 A; three-phase 1.0–2.3 A; motor-dependent. Supply current, not motor output rating.Digital interface: 6 control inputs; 6 control outputs; 2 pulse inputs and 2 pulse outputs.Drive application: EtherCAT driver for compatible AZ motors/actuators; motor and cables selected separately.
Industrial IO-Link master ifm part number AL1352; Operating voltage [V]: 20...30 DC; (US ; to SELV/PELV); Current consumption [mA]: 300...3900; (US); Max. current load total [A]: 3.6. Technical specifications, condition and supply feasibility are checked before ordering.
Operating voltage [V]: 20...30 DC; (US ; to SELV/PELV)Current consumption [mA]: 300...3900; (US)Max. current load total [A]: 3.6
Industrial software platform for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Application: IEC 61131-3 development environmentPlatform: 32-bit / 64-bit development editionsIDE licence: No IDE license required; target runtime licensing separate
Industrial Ethernet switch Phoenix Contact part number 1343031; Voltage - Input: 20 ~ 57V; Type: Switch - Unmanaged; Configuration: Fixed. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Input: 20 ~ 57VType: Switch - UnmanagedConfiguration: Fixed