Search by part number, manufacturer or technical specification, then narrow the results with filters.
Authenticity, technical version and delivery information
Authenticity and condition
Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.
Matching technical version
The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.
Delivery estimate before ordering
Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.
Schneider Electric / Relay output module / BMXDRA0804T. Manufacturer selection specifications and technical documents. Verify the module, rack architecture and connection accessories before ordering.
Industrial protocol gateway for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Serial interface: RS-232; RS-422; 2-wire RS-485Protocols: Modbus RTU Master / Slave; Modbus ASCII Master / SlavePower supply: 12–56 V DC primary and redundant inputs; TI-M6024 sold separately
Ultrasonic sensor Banner Engineering part number S18UBAQ; Response Frequency: 300kHz; Voltage - Supply: 10V ~ 30V; Sensor Type: Ultrasonic. Technical specifications, condition and supply feasibility are checked before ordering.
Industrial router Phoenix Contact part number 1102357; Modulation or Protocol: LTE; Frequency: 700MHz, 1.7GHz; Interface: Ethernet, RJ-45, RS-232. Technical specifications, condition and supply feasibility are checked before ordering.
Modulation or Protocol: LTEFrequency: 700MHz, 1.7GHzInterface: Ethernet, RJ-45, RS-232
Classic S7-200 digital expansion module. Specifications follow the August 2008 manufacturer manual. Verify host CPU expansion capacity, load limits and supplied revision before ordering; current lifecycle and supply are not established by this historical document.
Rated current per common: 10 A maximum; per-point limit remains 2 AController family: SIMATIC S7-200Discrete inputs: None
AH32AN02T-5A: 32-point digital output module. Selected specifications follow the exact manufacturer catalogue row. Confirm hardware/firmware compatibility, installation requirements and current supply before ordering.
Output signals: NPN sink; 12 to 24 VDC, 0.1 ACurrent rating scope: Catalogue Signals column; aggregate/common limits require the exact hardware manualInternal power consumption: 0.4 W
Industrial machine-vision camera Omron part number FHV7H-M063R-S06; Voltage - Supply: 21.6 ~ 26.4VDC; Type: Imaging Camera; Installation Distance: 102.0mm ~ 650.0mm. Technical specifications, condition and supply feasibility are checked before ordering.
Industrial PLC controller Allen-Bradley part number 1769-L33ERM; Device does not consume power: No; Isolation: 30V(cont),Basic Insulation,USB; Memory: 2MB. Technical specifications, condition and supply feasibility are checked before ordering.
Device does not consume power: NoIsolation: 30V(cont),Basic Insulation,USBMemory: 2MB
Industrial software licence ifm part number QMR001; User interface: user-specific visualisation of dashboards; Application: condition monitoring in real time (Real Time Maintenance); Configuration: definition of connection losses and limit values; user-specific setting of the alarm function. Technical specifications, condition and supply feasibility are checked before ordering.
User interface: user-specific visualisation of dashboardsApplication: condition monitoring in real time (Real Time Maintenance)Configuration: definition of connection losses and limit values; user-specific setting of the alarm function
Industrial pressure sensor Honeywell part number MIPAM1XX010BAAAX; Voltage - Supply: 4.75V ~ 5.25V; Applications: Medical Ventilation; Pressure Type: Absolute. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Supply: 4.75V ~ 5.25VApplications: Medical VentilationPressure Type: Absolute