ifm PX3228

- Manufacturer
- ifm
- Manufacturer part number
PX3228- Description
- pressure transmitter with ceramic measuring cell, PA-010WRBN14-A-ZVG/US/ /V
- Manufacturer standard lead time
- Manufacturer confirmation required; not a guaranteed delivery date.
Product specifications
- Number of inputs and outputs
- Number of analogue outputs: 1
- Measuring range
- 0...100 inH2O: 0...25 kPa
- Process connection
- threaded connection 1/4" NPT external thread internal thread:M5
- Special feature
- Gold-plated contacts
- Application
- for industrial applications
- Media
- liquids and gases
- Medium temperature [°C]
- -25...90
- Min. burst pressure
- 12043 inH2O: 3 MPa
- Pressure rating
- 2400 inH2O: 1 MPa
- Type of pressure
- relative pressure
- Operating voltage [V]
- 9.6...32 DC
- Min. insulation resistance [MΩ]
- 100; (500 V DC)
- Protection class
- III
- Reverse polarity protection
- yes
- Total number of outputs
- 1
- Output signal
- analogue signal
- Number of analogue outputs
- 1
- Analogue current output [mA]
- 4...20
- Max. load [Ω]
- 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA)
- Overload protection
- yes
- Repeatability [% of the span]
- < 0,15; (with temperature fluctuations < 10 K)
- Characteristics deviation [% of the span]
- < ± 0,35 (BFSL) / < ± 0,75 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
- Long-term stability [% of the span]
- < ± 0,05; (per 6 months)
- Temperature coefficient zero point [% of the span / 10 K]
- 0,2; (0...80 °C)
- Temperature coefficient span [% of the span / 10 K]
- 0,3; (0...80 °C)
- Step response time analogue output [ms]
- 3
- Ambient temperature [°C]
- -25...80
- Storage temperature [°C]
- -40...100
- Protection
- IP 65
- EMC
- EN 61000-4-2 ESD: 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 30 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-6 HF conducted: 10 V; radiation of interference: according to the automotive directive 2004/104/EC / CISPR 25; immunity: according to the automotive directive 2004/104/EC / ISO 11452-2; HF radiated: 100 V/m; pulse resistance: ISO 7637-2 / severity level 3
- Shock resistance
- DIN IEC 68-2-27: 50 g (11 ms)
- Vibration resistance
- DIN IEC 68-2-6: 20 g (10...2000 Hz)
- MTTF [years]
- 555
- Pressure Equipment Directive
- Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
- Weight [g]
- 212
- Housing
- cylindrical
- Dimensions [mm]
- Ø 30 / L = 79.5
- Materials
- stainless steel (316L/1.4404); FKM; PA; EPDM/X
- Materials (wetted parts)
- stainless steel (303/1.4305); ceramics; FKM
- Min. pressure cycles
- 100 million
- Restrictor element integrated
- no (can be retrofitted)
- Pack quantity
- 1 pcs.
- Connector
- 1 x M12; coding: A; Contacts: 4, gold-plated
Documents and media
Price and availability
Checking member pricing…
Supply, condition, exact revision and delivery are confirmed before accepting the order. Catalog presence does not mean local stock.