ARAN VISIONAccountQuote basketفارسی

ifm PQS812

ifm PQS812
Manufacturer
ifm
Manufacturer part number
PQS812
Description
Pressure sensor for pneumatics, PQ-010-KHR18-MFPKG/AS/
Manufacturer standard lead time
Manufacturer confirmation required; not a guaranteed delivery date.

Product specifications

Number of inputs and outputs
Number of digital outputs: 2
Measuring range
-1...10 bar: -0.1...1 MPa
Process connection
threaded connection G 1/8 internal thread (2x)
Special feature
Gold-plated contacts
Application
for industrial applications
Media
compressed air; nitrogen (N2)
Conditionally suitable for
other media on request
Medium temperature [°C]
0...60
Min. burst pressure
20 bar: 2 MPa
Pressure rating
15 bar: 1.5 MPa
Vacuum resistance
-1000 mbar: -0.1 MPa
Type of pressure
relative pressure; vacuum
Operating voltage [V]
18...30 DC
Current consumption [mA]
< 30
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
0.3
Integrated watchdog
yes
Total number of outputs
2
Output signal
switching signal; IO-Link; (configurable)
Electrical design
PNP/NPN; (configurable)
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2.5
Permanent current rating of switching output DC [mA]
100
Switching frequency DC [Hz]
< 170
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Set point SP
-1...10 bar: -0.1...1 MPa
In steps of
0.01 bar: 0.001 MPa
Switch point accuracy [% of the span]
< ± 0,5
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K:)
Characteristics deviation [% of the span]
< ± 0,5; (including linearity, hysteresis and repeatability)
Linearity deviation [% of the span]
< ± 0.5 % (limit value setting according to DIN EN IEC 62828-1)
Hysteresis deviation [% of the span]
< ± 0,25
Long-term stability [% of the span]
< ± 0,1; (per year)
Temperature coefficient zero point [% of the span / 10 K]
0,2
Temperature coefficient span [% of the span / 10 K]
0,2
Response time [ms]
6
Damping process value dAP [s]
0...4
Damping for the analogue output dAA [s]
0...99.99
Parameter setting options
display can be rotated and switched off; Teach function; simulation function; diagnostic function
Communication interface
IO-Link
Transmission type
COM3 (230,4 kBaud)
IO-Link revision
1.1.3
SDCI standard
IEC 61131-9: 2019-06
Profiles
Smart Sensor - SSP 4.1.1: Measuring and Switching Sensor, 1 channel; BLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis; Extension: Quantity detection, switches when value exceeds the setpoint; Function: Locator; Function: ProductURI
SIO mode
yes
Required master port type
A
Process data analogue
1
Process data binary
2
Min. process cycle time [ms]
0.6
IO-Link resolution pressure [bar]
0.001
IO-Link process data (cyclical)
function: bit length; pressure: 16; device status: 4; SSC1.1: 1; SSC1.2: 1
IO-Link functions (acyclical)
application specific tag; internal temperature; Medium temperature
Supported DeviceIDs
Type of operation: DeviceID; default: 1617
Ambient temperature [°C]
0...60
Storage temperature [°C]
-25...85
Protection
IP 65
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]
508
UL approval
UL approval no.: J065; File number UL: E174189
Pressure Equipment Directive
Sound engineering practice; can be used for stable gases fluid group 2
Weight [g]
52
Housing
rectangular
Dimensions [mm]
37.7 x 30 x 38.6
Materials
PBT; PC; TPE; NBR; FKM; brass; silicon (coated)
Materials (wetted parts)
PBT; FKM; brass; silicon (coated)
Min. pressure cycles
50 million
Display
Display 1": 128 x 96 pixels; switching status: 2 x LED, yellow
Display unit
bar; MPa; mmHg; kgf/cm²
Items supplied
head cap screw: 2 x (M3 x 8 mm)
Pack quantity
1 pcs.
Connector
1 x M8; coding: A; Contacts: 4, gold-plated

Documents and media

Price and availability

Checking member pricing…

Supply, condition, exact revision and delivery are confirmed before accepting the order. Catalog presence does not mean local stock.