Specialist electrical and industrial automation store
فارسی

Industrial pressure sensor ifm model PN2694

Industrial pressure sensor ifm model PN2694,  Part number PN2694

Check the part number and technical specifications before selection; an image alone is not sufficient for matching.

Manufacturer part number
PN2694
Manufacturer
ifm
ARAN VISION part number
AV-FEED-12951PF
Product description
Industrial pressure sensor ifm part number PN2694; Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1; Measuring range: -1...10 bar: -14.6...145 psi: -100...1000 kPa: -0.1...1 MPa; Process connection: threaded connection 1/4" NPT external thread. Technical specifications, condition and supply feasibility are checked before ordering.
Manufacturer standard lead time
Manufacturer confirmation required

Manufacturer replenishment time; delivery to you is confirmed separately.

Product attributes

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-1...10 bar: -14.6...145 psi: -100...1000 kPa: -0.1...1 MPa
Process connection
threaded connection 1/4" NPT external thread
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
liquids and gases
Medium temperature [°C]
-25...80
Min. burst pressure
150 bar: 2175 psi: 15 MPa
Pressure rating
75 bar: 1087 psi: 7.5 MPa
Vacuum resistance
-1000 mbar: -0.1 MPa
Type of pressure
relative pressure; vacuum
MAWP for applications according to CRN
50 bar: 725 psi: 5 MPa
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
< 35
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
0.3
Integrated watchdog
Yes
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
250
Switching frequency DC [Hz]
< 500
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable 1:5)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable 1:5)
Min. load resistance [Ω]
2000
Short-circuit protection
Yes
Type of short-circuit protection
pulsed
Overload protection
Yes
Analogue start point
-1...8 bar: -14.6...116 psi: -0.1...0.8 MPa
Analogue end point
1...10 bar: 14.6...145 psi: 0.1...1 MPa
Set point SP
-0.94...10 bar: -13.6...145 psi: -0.094...1 MPa
Reset point rP
-0.98...9.96 bar: -14.2...144.4 psi: -0.098...0.996 MPa
Min. difference between SP and rP
0.06 bar: 0.6 psi: 0.006 MPa
In steps of
0.02 bar: 0.2 psi: 0.002 MPa
Min. difference between SP and rP
0.06 bar: 0.6 psi: 0.005 MPa
In steps of
0.01 bar: 0.1 psi: 0.001 MPa
Switch point accuracy [% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]
< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]
< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Temperature coefficient span [% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Notes on the accuracy / deviation
switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response time [ms]
< 1.5
Delay time programmable dS, dr [s]
0...50
Damping process value dAP [s]
0...4
Damping for the analogue output dAA [s]
0...4
Max. response time analogue output [ms]
3
Parameter setting options
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
SIO mode
Yes
Required master port type
A; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operation: DeviceID; Factory setting / CMPT = 2: 473; Status_B High Resolution / CMPT = 3: 989
Note
For further information please see the IODD PDF file under "Downloads"
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
Min. process cycle time [ms]
2.3
IO-Link resolution pressure [bar]
0.01
IO-Link process data (cyclical)
function: bit length; pressure: 14; binary switching information: 2
IO-Link functions (acyclical)
application specific tag
Profiles
Smart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis
Min. process cycle time [ms]
3
IO-Link resolution pressure [bar]
0.005
IO-Link process data (cyclical)
function: bit length; pressure: 16; device status: 4; binary switching information: 2
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection
IP 65; IP 67
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27: 50 g (11 ms)
Report a product information error
Documents and technical resources
ARAN VISION product sheetView and print specifications
Manufacturer datasheetOpen manufacturer datasheet
Official product pageifm

Source checked: 2026-09-10

Product questions

Send the part number and your question to support to check compatibility, lead time or specifications.

Additional information and order matching

The revision, condition, delivery time and required documentation must be confirmed before the order is finalised. Export classifications and approvals are provided only where valid evidence is available.

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version

The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.

Delivery estimate before ordering

Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.

Technical code verification

Model, revision and equipment compatibility are checked before final confirmation.

Clear product condition

New, surplus or refurbished condition and warranty terms are stated in the quotation.

Products outside the catalog

If this model is unavailable, send the part number or nameplate photo for custom sourcing.

Related products