ifm
Manufacturer part number
PN2693
Description
Pressure sensor with display, PN-025-REN14-MFRKG/US/ /V
Manufacturer standard lead time
Manufacturer confirmation required; not a guaranteed delivery date.

Product specifications

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-1...25 bar: -14.5...362.5 psi: -0.1...2.5 MPa
Process connection
threaded connection 1/4" NPT external thread
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
liquids and gases
Medium temperature [°C]
-25...80
Min. burst pressure
350 bar: 5075 psi: 35 MPa
Pressure rating
150 bar: 2175 psi: 15 MPa
Vacuum resistance
-1000 mbar: -0.1 MPa
Type of pressure
relative pressure; vacuum
MAWP for applications according to CRN
70 bar: 1015 psi: 7 MPa
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
< 35
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
0.3
Integrated watchdog
yes
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
250
Switching frequency DC [Hz]
< 500
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable 1:5)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable 1:5)
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Analogue start point
-1...20 bar: -14.5...290 psi: -0.1...2 MPa
Analogue end point
4...25 bar: 58...362.5 psi: 0.4...2.5 MPa
Set point SP
-0.85...25 bar: -12...362.5 psi: -0.085...2.5 MPa
Reset point rP
-0.95...24.9 bar: -13.5...361 psi: -0.095...2.49 MPa
Min. difference between SP and rP
0.15 bar: 1.5 psi: 0.015 MPa
In steps of
0.05 bar: 0.5 psi: 0.005 MPa
Set point SP
-0.84...25 bar: -12.2...362.6 psi: -0.084...2.5 MPa
Reset point rP
-0.95...24.9 bar: -13.7...361.1 psi: -0.095...2.49 MPa
Min. difference between SP and rP
0.11 bar: 1.5 psi: 0.011 MPa
In steps of
0.01 bar: 0.1 psi: 0.001 MPa
Switch point accuracy [% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]
< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]
< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Temperature coefficient span [% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Notes on the accuracy / deviation
switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response time [ms]
< 1.5
Delay time programmable dS, dr [s]
0...50
Damping process value dAP [s]
0...4
Damping for the analogue output dAA [s]
0...4
Max. response time analogue output [ms]
3
Parameter setting options
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
SIO mode
yes
Required master port type
A; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operation: DeviceID; Factory setting / CMPT = 2: 472; Status_B High Resolution / CMPT = 3: 988
Note
For further information please see the IODD PDF file under "Downloads"
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
Min. process cycle time [ms]
2.3
IO-Link resolution pressure [bar]
0.01
IO-Link process data (cyclical)
function: bit length; pressure: 14; binary switching information: 2
IO-Link functions (acyclical)
application specific tag
Profiles
Smart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis
Min. process cycle time [ms]
3
IO-Link process data (cyclical)
function: bit length; pressure: 16; device status: 4; binary switching information: 2
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection
IP 65; IP 67
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3