ifm IGM204

- Manufacturer
- ifm
- Manufacturer part number
IGM204- Description
- Inductive sensor, IGK3008BBPKG/60V/V4A/US-104
- Manufacturer standard lead time
- Manufacturer confirmation required; not a guaranteed delivery date.
Product specifications
- Electrical design
- PNP
- Output function
- normally open
- Sensing range [mm]
- 8
- Housing
- threaded type
- Dimensions [mm]
- M18 x 1 / L = 70
- Special feature
- Gold-plated contacts; Increased sensing range
- Application
- Use in mobile and harsh applications
- Operating voltage [V]
- 10...60 DC
- Current consumption [mA]
- < 10
- Protection class
- II
- Reverse polarity protection
- yes
- Max. voltage drop switching output DC [V]
- 2.5
- Permanent current rating of switching output DC [mA]
- 200
- Switching frequency DC [Hz]
- 200
- Short-circuit protection
- yes
- Type of short-circuit protection
- pulsed
- Overload protection
- yes
- Real sensing range Sr [mm]
- 8 ± 10 %
- Operating distance [mm]
- 0...6.48
- Increased sensing range
- yes
- Correction factor
- steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3
- Hysteresis [% of Sr]
- 1...20
- Switch point drift [% of Sr]
- -10...10
- Ambient temperature [°C]
- -40...85
- Protection
- IP 67; IP 69K
- EMC
- automotive area; noise emission and noise immunity: ECE R10: E1 type approval; noise immunity according to DIN ISO 11452-2: 100 V/m; conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4) and ISO16750-2: 2012 (load dump); pulse: 1 2a 2b 3a 3b 4 Load dump; severity level: III III III III III III Test A; failure criterion: C A C A A C C; EN 61000-4-2 ESD: 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 10 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-5 Surge: 0,5 kV mains line to line; EN 61000-4-6 HF conducted: 10 V; EN 55011: class B
- Fast temperature change
- EN 60068-2-14 Na: TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
- Salt spray test
- EN 60068-2-52 Kb: severity level 5 (4 test cycles)
- MTTF [years]
- 1079
- UL approval
- Ta: 0...40 °C; Enclosure type: Type 1; UL approval no.: A050; File number UL: E174191
- Weight [g]
- 53.4
- Mounting
- flush mountable
- Thread designation
- M18 x 1
- Materials
- housing: stainless steel (316L/1.4404); sensing face: LCP white; LED window: PEI; lock nuts: brass white bronze coated
- Tightening torque [Nm]
- 50
- Display
- switching status: 4 x 90° LED, yellow
- Items supplied
- lock nuts: 2
- Remarks
- no parallel connection possible
- Pack quantity
- 1 pcs.
- Connector
- 1 x M12; coding: A; Contacts: 3, gold-plated
Documents and media
Price and availability
Checking member pricing…
Supply, condition, exact revision and delivery are confirmed before accepting the order. Catalog presence does not mean local stock.