ARAN VISION logo

ARAN VISION

Product specification sheet

2080-MOT-HSCDocument: AV-FEED-PLSBCY
High-speed counter module Allen-Bradley model 2080-MOT-HSC,  Part number 2080-MOT-HSC

Allen-Bradley · PLC and HMI

High-speed counter module Allen-Bradley model 2080-MOT-HSC

High-speed counter module Allen-Bradley part number 2080-MOT-HSC; I/O Isolation: None; I/O Status Indication: LED; Bus current draw: 60mA @ 3.3V DC. Technical specifications, condition and supply feasibility are checked before ordering.

Manufacturer part number
2080-MOT-HSC
Brand
Allen-Bradley
Category
PLC and HMI
Catalog status
Available on request

Technical specifications

Lifecycle Status
Active
Repair Options Available
No
I/O Isolation
None
I/O Status Indication
LED
Bus current draw
60mA @ 3.3V DC
Conducted RF immunity
IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Depth
20 mm
Digital inputs configurable
true
Digital outputs configurable
true
EFT/B immunity
IEC 61000-4-4: ±2kV @ 5kHz on signal ports
Emissions
CISPR 11 (IEC 61000-6-4): Class A
Enclosure type rating
Meets IP20
ESD immunity
IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
Height
62 mm
Input current range
2 mA
Input frequency, max
250 kHz (50% duty)
Input impedance, nom
3580 Ω
Input voltage range
0...30V DC
Isolation voltage
Input module: 50V (continuous), Basic Insulation Type, Inputs/Outputs to Backplane. Type tested for 60s @ 720V DC, Inputs/Outputs to Backplane
Maximum count
48 bit
Nonoperating temperature
-40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
North American temperature code
T4
Number of inputs
1 Quadrature (ABZ) differential input
Number of outputs
16 (1 physical output, 15 virtual)
Off-state leakage current
0.5 mA
Off-state voltage, max
1.0V DC
On-state current, min
2 mA
On-state voltage drop, max
0.5V DC
ON-state voltage range
2.6...30V DC
Operating temperature
-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Output on-state current
0.5 A
Output voltage range
5...30V DC
Phase separation, min
500 ns
Pulse width, min
2 µs
Radiated RF immunity
IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
Redundancy
false

This sheet provides a quick technical summary. For design, installation and final selection, review the latest official manufacturer documentation and verify the complete part number.