نشان ARAN VISION

ARAN VISION

Datasheet فنی محصول

2080-MOT-HSCDocument: AV-FEED-PLSBCY
High-speed counter module Allen-Bradley model 2080-MOT-HSC,  Part number 2080-MOT-HSC

Allen-Bradley · PLC and HMI

High-speed counter module Allen-Bradley model 2080-MOT-HSC

High-speed counter module Allen-Bradley part number 2080-MOT-HSC; Lifecycle Status: Active; Repair Options Available: No; I/O Isolation: None. Technical specifications, condition and supply feasibility are checked before ordering.

Manufacturer part number
2080-MOT-HSC
Brand
Allen-Bradley
Category
PLC and HMI
Status فهرست
Available on request

Specifications فنی

Lifecycle Status
Active
Repair Options Available
No
I/O Isolation
None
I/O Status Indication
LED
Bus current draw
60mA @ 3.3V DC
Conducted RF immunity
IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Depth
20 mm
Digital inputs configurable
true
Digital outputs configurable
true
EFT/B immunity
IEC 61000-4-4: ±2kV @ 5kHz on signal ports
Emissions
CISPR 11 (IEC 61000-6-4): Class A
Enclosure type rating
Meets IP20
ESD immunity
IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
Height
62 mm
Input current range
2 mA
Input frequency, max
250 kHz (50% duty)
Input impedance, nom
3580 Ω
Input voltage range
0...30V DC
Isolation voltage
Input module: 50V (continuous), Basic Insulation Type, Inputs/Outputs to Backplane. Type tested for 60s @ 720V DC, Inputs/Outputs to Backplane
Maximum count
48 bit
Nonoperating temperature
-40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
North American temperature code
T4
Number of inputs
1 Quadrature (ABZ) differential input
Number of outputs
16 (1 physical output, 15 virtual)
Off-state leakage current
0.5 mA
Off-state voltage, max
1.0V DC
On-state current, min
2 mA
On-state voltage drop, max
0.5V DC
ON-state voltage range
2.6...30V DC
Operating temperature
-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Output on-state current
0.5 A
Output voltage range
5...30V DC
Phase separation, min
500 ns
Pulse width, min
2 µs
Radiated RF immunity
IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
Redundancy
false

این برگه, خلاصه فارسی Specifications محصول for دسترسی سریع است. for طراحی, Mounting and انتخاب نهایی, آخرین Official manufacturer documentation and تطابق Complete Part number بررسی شود.