Industrial communication module Allen-Bradley model 1756-CNB,  Part number 1756-CNB

Allen-Bradley · Machine safety

Industrial communication module Allen-Bradley model 1756-CNB

Industrial communication module Allen-Bradley part number 1756-CNB; Communication: ControlNet; Interface: 1 ControlNet BNC; Number Of Channels: 1. Technical specifications, condition and supply feasibility are checked before ordering.

Manufacturer part number
1756-CNB
Brand
Allen-Bradley
Category
Machine safety
Catalog status
Available on request

Technical specifications

Lifecycle Status
Discontinued
Repair Options Available
Yes
Communication
ControlNet
Interface
1 ControlNet BNC
Number Of Channels
1
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Connections supported, max
64 maximum
ControlNet cable
1786-RG6 quad shield RG6 coaxial cable
ControlNet port
1 ControlNet BNC
Current draw
970mA @ 5.1V DC, 1.7mA @ 24V DC
EFT/B immunity
±3kV @ 5kHz on ControlNet ports
Emissions
CISPR 11: Class A
Enclosure type rating
None (open-style)
ESD immunity
6 kV contact discharges, 8 kV air discharges
IO link master
false
Isolation voltage
Standard: 30V (continuous), basic insulation type, ControlNet network to, backplane, Redundant: 30V (continuous), basic insulation type, ControlNet A/B to, backplane, and ControlNet A to ControlNet B, USB to backplane and USB to ControlNet, No isolation b
Logix communication connections range
40...48
Module location
Chassis based, any slot
NAP cable
1786-CP
NAP port
1 NAP RJ45
Number of nodes, max
99 nodes
Operating temperature
0 to 60 °C
Power dissipation
5.1 W
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Radio standard Bluetooth
false
Radio standard GPRS
false
Radio standard GSM
false
Radio standard UMTS
false
Radio standard Wi-Fi 802.11
false
Redundancy
false
Relative humidity
5...95% noncondensing
Shock
Operating: 30 G, Non operating: 50 G
Slot width
1
Storage temperature
-40 to 85 °C
Supporting protocol for ASI
false
Supporting protocol for AS-Interface Safety at Work
false