- Number of inputs and outputs
- Number of digital outputs: 2; Number of analogue outputs: 1
- Measuring range [gph]
- 30...1620
- Process connection
- threaded connection 1" NPT internal thread
- Special feature
- Gold-plated contacts
- کاربرد
- for industrial applications
- Media
- Liquids; water; glycol solutions; coolants; oil (viscosity 10 mm²/s at 104 °F); oil (viscosity 46 mm²/s at 104 °F)
- Note on media
- oil 1 with viscosity: 10 mm²/s (104 °F); oil 2 with viscosity: 46 mm²/s (104 °F)
- Medium temperature [°F]
- 14...212
- Pressure rating
- 25 bar: 2.5 MPa
- MAWP for applications according to CRN [bar]
- 25
- ولتاژ کاری
- 18...30 DC; (to SELV/PELV)
- Current consumption [mA]
- < 50
- Protection class
- III
- حفاظت در برابر پلاریته معکوس
- دارد
- Power-on delay time [s]
- < 3
- Total number of outputs
- 2
- Output signal
- switching signal; analogue signal; frequency signal; IO-Link; (configurable)
- تعداد خروجی دیجیتال
- 2
- Output function
- normally open / normally closed; (parameterisable)
- Max. voltage drop switching output DC [V]
- 2
- Permanent current rating of switching output DC [mA]
- 150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
- Switching cycles (mechanical)
- 10 million
- Number of analogue outputs
- 1
- Analogue current output [mA]
- 4...20
- Max. load [Ω]
- 500
- حفاظت اتصال کوتاه
- دارد
- Overload protection
- دارد
- Frequency of the output [Hz]
- 0...10000
- Display range
- 0...1940 gph: 0...32.4 gpm
- وضوح اندازهگیری
- 10 gph: 0.1 gpm
- Set point SP
- 10...1620 gph: 0.2...27 gpm
- Reset point rP
- 0...1610 gph: 0...26.8 gpm
- Frequency end point, FEP
- 110...1620 gph: 1.8...27 gpm
- In steps of
- 10 gph: 0.1 gpm
- Frequency at the end point FRP [Hz]
- 10...10000
- Measuring dynamics
- 1:50
- Measuring range [°F]
- 14...212
- Display range [°F]
- -26...252
- Resolution [°F]
- 2
- Set point SP [°F]
- 16...212
- Reset point rP [°F]
- 14...210
- In steps of [°F]
- 2
- Frequency start point, FSP [°F]
- 14...172
- Frequency end point, FEP [°F]
- 54...212
- Accuracy (in the measuring range)
- ± (4 % MW + 1 % MEW); (Q > 2 l/min; medium and operating temperature: +71,6 °F ± 4K)
- Repeatability
- ± 1 % MEW
- Temperature drift
- 0,9802 °F / K
- Accuracy [K]
- 3 K (77 °F; Q > 1 l/min)
- Response time [s]
- 0.01
- Damping process value dAP [s]
- 0...5
- Damping for the analogue output dAA [s]
- 0...5
- Dynamic response T05 / T09 [s]
- T09 = 120 (Q > 1 l/min)
- Parameter setting options
- hysteresis / window; normally open / normally closed; switching logic; current output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour
- رابط ارتباطی
- IO-Link
- Transmission type
- COM2 (38,4 kBaud)
- IO-Link revision
- 1.1
- SDCI standard
- IEC 61131-9 CDV
- Profiles
- Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
- SIO mode
- دارد
- Required master port type
- A
- Process data analogue
- 2
- Process data binary
- 2
- Min. process cycle time [ms]
- 3.2
- Supported DeviceIDs
- Type of operation: DeviceID; default: 568
- Ambient temperature [°F]
- 32...140
- Note on ambient temperature
- medium temperature < 176 °F; medium temperature < 212 °F: 32...104 °F
- Storage temperature [°F]
- 5...176
- درجه حفاظت
- IP 65; IP 67
- EMC
- DIN EN 61000-6-2; DIN EN 61000-6-3
- Shock resistance
- DIN EN 60068-2-27: 20 g (11 ms)
- Vibration resistance
- DIN EN 60068-2-6: 5 g (10...2000 Hz)
- MTTF [years]
- 145
- UL approval
- UL approval no.: I006; File number UL: E174189
- Pressure Equipment Directive
- Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
- Weight [g]
- 1292.4
- Materials
- stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
- Materials (wetted parts)
- stainless steel (316 / 1.4401); stainless steel (316L/1.4404); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
- Display
- Display unit: 3 x LED, green; switching status: 2 x LED, yellow; measured values: alphanumeric display, red/green 4-digit; programming: alphanumeric display, 4-digit
- Remarks
- Recommendation: use a 200-micron filter.; All data refer to water (68 °F).; MW = measured value; MEW = Final value of the measuring range
- Notes
- Please note the changed housing design!